Rolence Enterprise Inc.
Home> Products> Ultrasonic Scalers> Magnetostrictive System Scaler> Compact Dental Ultrasonic Scaler Magneto
Compact Dental Ultrasonic Scaler Magneto
Compact Dental Ultrasonic Scaler Magneto
Compact Dental Ultrasonic Scaler Magneto

Compact Dental Ultrasonic Scaler Magneto

Get Latest Price
Payment Type:T/T,Credit Card
Incoterm:FOB,EXW,CFR,CIF,FCA,FAS,CPT,CIP
Transportation:Ocean,Air,Express
Port:Port of Keelung
Product Attributes

Model No.MS-30

BrandELiTEDENT

Place Of OriginTaiwan, China

Kind Of PowerElectricity

Warranty Service1 Year

After-sales ServiceOnline Technical Support, Onsite Training, Return And Replacement

MaterialMetal, Plastic

Shelf Life1years

Product Quality CertificationCe

Medical Device ClassificationClass Ii

Safety StandardNone

Size15.5cm (W) x 12.8cm (H) x 10.5cm (D)

Weight0.85 kg

Packaging & Delivery
Selling Units : Piece/Pieces
Package Type : By paper box
Download :
Rolence Enterprise Corporate Video
Ultrasonic Scalers Video
Product Description

Rolence ELITEDENT® MS-30

1. DETACHABLE HANDPIECE: Can be autoclaved in high temperature 135℃.
2. DUAL FREQUENCY: Accepting 25K and 30K insert with auto-detecting, make user comfortable.
3. AUTO POWER BOOST: Provides auto upscaling power in gentle to remove heavy calculus and cleaning
4. EXTERNAL FILTERS: Effectively block impurities in water, simple set up, filter can be disposable.
5. CONTROL PANEL: Simple interface to regulate scaling power and adjust water volume.


Prior to installation and start-up of the Ultrasonic Scaler, carefully read the instructions provided herein!

 

Precautions for All Systems

1. Do not place the Ultrasonic Scaler on or next to a radiator or other heat source. Excessive heat may damage the ultrasonic scaler’s electronics. Place the ultrasonic scaler where air is free to circulate on all sides and beneath it. Do not cover vents on rear panel.

2. The ultrasonic scaler is portable, but must be handled with care when moving.

3. Equipment and dental water supply system maintenance are strongly recommended.

4. Close the water shut-off valve in the dental water supply system every night before leaving the office.

5. The use of an in-line water filter is recommended.

6. Used for the intended purpose only. The Ultrasonic Scaler must be used by other than qualified and trained personnel, in medical facilities.

7. Grounding reliability can only be achieved when the Ultrasonic Scaler is connected to an equivalent receptacle marked Hospital Only or Hospital Grade.

 

Precautions for Ultrasonic Prophylaxis Procedures

Before first use, clean, disinfect and sterilize new or repaired handpieces and instruments you wish to use with the Ultrasonic Scaler.

Always examine the Ultrasonic Scaler and ultrasonic tips before commencing treatment. A damaged Ultrasonic Scaler or damaged tip must not be used.

Ultrasonic tips that have been bent, damaged, or reshaped are susceptible to in-use breakage and should be discarded and replaced immediately.

 

Introduction

Rolence Enterprise Inc. is an ISO 13485 certified manufacturer of Ultrasonic Scalers. All the products are FDA registered and compliant with EN standard (CE Marking).

 

Conformance to Standards:

The Rolence® ELiTEDENT® MS-30 Ultrasonic Scaler conforms to IEC60601-1-2:2007 and IEC60601-1-1:2006.

The Ultrasonic Scaler is CE marked corresponding to European Medical Device Directive (93/42/EEC)

 

Supplies and Replacement Parts

Contact your local Rolence dealer to order supplies or replacement parts. There are no serviceable parts included in this device. Please contact your dealer to acquire all repairing service and technique supports.

 

Caution: Equipment not suitable for use in the presence of flammable anesthetic mixture with air or with nitrous oxide.

Caution: U.S. federal law restricts this device to sale by or on the order of a dental professional.

 

Contraindications

Ultrasonic Systems should not be used for restorative dental procedures involving the condensation of amalgam.

The Ultrasonic Scaler is designed to work with all Cavitron® (remark) 25 kHz and 30 kHz frequency inserts. For optimum performance please use only qualified inserts supplied by Cavitron® or Rolence®.

Do not use the Ultrasonic Scaler if the patient or operator is wearing a pacemaker.

Remark: Cavitron® is a registered trademark of Dentsply® International, Inc

 

Warnings

Persons who are fitted with cardiac pacemakers, defibrillators and other active implanted medical devices, have been cautioned that some types of electronic equipment might interfere with the operation of the device. We recommend that the

MS handpiece cable kept at least 6 to 9 inches (15 to 23 cm) away from any device and their leads during use.

‧ During using the unit, make sure that water is flowing continuously. If the handpiece overheats please check the water supply, and stop using the Ultrasonic Scaler for a while.


#Ultrasonic Scaler #Ultrasonic Scalers #Scaling Tip #Accessories


Home> Products> Ultrasonic Scalers> Magnetostrictive System Scaler> Compact Dental Ultrasonic Scaler Magneto
Send Inquiry
*
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send