Built-in Type Magneto Dental Scaler
Get Latest PricePayment Type: | T/T,Credit Card |
Incoterm: | FOB,EXW,CFR,CIF,FCA,FAS,CPT,CIP |
Transportation: | Ocean,Air,Express |
Port: | Port of Keelung |
Payment Type: | T/T,Credit Card |
Incoterm: | FOB,EXW,CFR,CIF,FCA,FAS,CPT,CIP |
Transportation: | Ocean,Air,Express |
Port: | Port of Keelung |
Model No.: MS-10B
Brand: ELiTEDENT
Place Of Origin: Taiwan, China
Kind Of Power: Electricity
Warranty Service: 1 Year
After-sales Service: Online Technical Support, Onsite Training, Return And Replacement
Material: Metal, Plastic
Shelf Life: 1years
Product Quality Certification: Ce
Medical Device Classification: Class Ii
Safety Standard: None
Size: 3.4 cm (H) x 10.0 cm (D) x 12.7 cm (W)
Unpacking the System Carefully unpack your ELiTEDENT® Ultrasonic Scaler and verify that all components and Accessories are included: 1. ELiTEDENT® MS-10B Ultrasonic Scaler main control unit. 2. Handpiece set with tubing. 3. Variable Resistor with knob. 4. Users Manuals.
Safety Precautions Prior to installation and start-up of the Ultrasonic Scaler, carefully read the instructions provided herein! Precautions for All Systems 1. Do not place the Ultrasonic Scaler on or next to a radiator or other heat source. Excessive heat may damage the ultrasonic scaler’s electronics. 2. Equipment and dental water supply system maintenance are strongly recommended. 3. Close the water shut-off valve in the dental water supply system every night before leaving the office. 4. The use of an in-line water filter is recommended. 5. Used for the intended purpose only. The Ultrasonic Scaler must be used by other than qualified and trained personnel, in medical facilities. 6. Grounding reliability can only be achieved when the Ultrasonic Scaler is connected to an equivalent receptacle marked Hospital Only or Hospital Grade. Precautions for Ultrasonic Prophylaxis Procedures 1. Before first use, clean, disinfect and sterilize new or repaired handpieces and instruments you wish to use with the Ultrasonic Scaler. 2. Always examine the unit and ultrasonic tips before commencing treatment. A damaged Ultrasonic Scaler or damaged tip must not be used. 3. Ultrasonic tips that have been bent, damaged, or reshaped are susceptible to in-use breakage and should be discarded and replaced immediately. 4. Retract the lips, cheeks and tongue to prevent contact with the ultrasonic tip whenever it is placed in the patient's mouth. Introduction Rolence Enterprise Inc. is an ISO 9001(2008), ISO 13485(2003) certified manufacturer of Ultrasonic Scalers. All the products are FDA registered and compliant with EN standard (CE Marking). Conformance to Standards: The Rolence® ELiTEDENT® MS-10B Ultrasonic Scaler conforms to IEC60601-1-2:2001 and IEC60601-1-1:2000. The device is CE marked corresponding to European Medical Device Directive (93/42/EEC) Function The Ultrasonic Scaler is designed for use in prophylaxis treatments periodontia, and other areas of operative dentistry. When used in prophylaxis treatment, the unit operates with a fine warm water spray, requiring little of the physical exertion necessary with hand instruments. It easily and effectively removes stubborn calculus and stains both supragingivally and subgingivally, leaving crown and root surfaces clean and smooth. Installation Instructions General Information If the installation of your ELiTEDENT® MS-10B Ultrasonic Scaler is performed by someone other than trained Rolence® distributor personnel, care should be taken to observe the following requirements and recommendations. Water Line Requirements 1. Incoming water supply line pressure to the ultrasonic scaler must be 25 psi (172 kPa minimum) to 40 psi (276 kPa) maximum. If your dental water system's supply line pressure is above 60 psi, install a water pressure regulator on the water supply line to your Ultrasonic Scaler. 2. A manual shut-off valve on the dental water system supply line should be used so that the water can be completely shut-off when the office is unoccupied.